beautypg.com

Maxim Integrated 71M6541 Demo Board User Manual

Page 28

background image

71M6541 Demo Board REV 3.0 User’s Manual

28

Rev 4.0

state_bit_ar

y

Status of meter.
Nonvolatile.

Bits:
See table below.

0 = no errors

)30

unsigned

32

wh_im

Wh energy register.
Nonvolatile.

First 32-bit number is a count of
pulses, =3.2 Wh in 3-phase me-
ters, or 1 in 1-phase. A fractional
pulse is present in the CE data,
but not preserved.

n/a

)31

64

wh_ex

Wh exported energy
register. Nonvola-
tile.

Like wh_im

n/a

)32

64

varh_im

VARh register.
Nonvolatile.

Like wh_im

n/a

)33

64

varh_ex

VARh exported reg-
ister. Nonvolatile.

Like wh_im

n/a

)34

64

dmd_max

Maximum demand,
W

Units of w0sum

n/a

)35

signed

32

dmd_max_rtc

Time of maximum
demand.

Standard time and date struc-
ture.

year, month,
date, hour, min

)36..

3A

unsigned

7x8

v_bat

Battery voltage at
last measurement.
Volatile; not saved
on power failure.

0.1V

n/a

)3B

signed

8

acc_cnt

Count of accumula-
tion intervals since
reset, or last clear.
Cleared with )1=2 or
meter read. Volatile;
not saved on power
failure.

count

n/a

)3C

signed

32

tamper_sec

Counts seconds
that tamper errors
were asserted.
Cleared with )1=2 or
meter read. Nonvol-
atile.

This is a tamper measurement.

n/a

)3D

signed

32

sag_sec

Counts seconds
that voltage low
error occurred. or
meter read. Nonvol-
atile.

This is a power quality meas-
urement.

n/a

)3E

signed

32

in_sec

3

Counts seconds
that neutral current
error was asserted.
Cleared with )1=2 or
meter read. Nonvol-
atile.

This is a power quality meas-
urement.

n/a

)3F

signed

32

rtc_copy

Clock time and date
when data was last
read from the RTC.

Standard time and date struc-
ture. year, month, date, hour,
min, sec

n/a

)40..

45

unsigned

8*7

save_cnt

Number of power
register saves.

n/a

n/a

)46

unsigned

16

data_ok_reg

Checks data.

n/a

n/a

)47

unsigned

16

1

Valid only when autocalibration is integrated. Meters with metering equations with differential currents or voltages do not

normally support autocalibration.

2

Requires features not in some demo PCBs.