71M6541 Demo Board REV 3.0 User’s Manual

16

Rev 4.0

Commands for Controlling the Metering Values Shown on the LCD Display:

Step

Text or Nu-

merical Dis-

play

CLI

command

Displayed Parameter(s)

0

10000

00

M0

Meter ID

1

24.5 °C

01

M1

Temperature difference from calibration temperature.

2

59.9

02

M2

Frequency at the VA_IN input [Hz]

3

3.27 Whr

03

M3

Accumulated imported real energy [Wh]. The default display setting
after power-up or reset.

4

1.04 Whr

04

M4

Accumulated exported real energy [Wh].

5

2.21 VARhr

05

M5

Accumulated reactive energy [VARh].

6

0.95 VARhr

06

M6

Accumulated exported reactive energy [VARh].

7

4.11 VAhr

07

M7

Accumulated apparent energy [VAh].

8

0.7 hr

08

M8

Elapsed time since last reset or power up.

9

01:43:59

09

M9

Time of day (hh.mm.ss)

10

01.01.01

10

M10

Date (yy.mm.dd)

11

0.62

11

1

M11.P

Power factor (P = phase)

12

0

M12

Not used in the 71M6541

13

120

13

M13

Zero crossings of the mains voltage

14

48
14

M14

Duration of sag or neutral current [s]

15

24.10 A

15

M15.P

RMS current (P = phase)

16

241.27 V

16

M16

RMS voltage

17

3.34 V

17

M17

Battery voltage

18

241.34 W

18

1

M18

Momentary power in W (P = phase)

19

50400 W

19

M19

Demand

20

88.88.88
88.88.88
88.88.88

M20

LCD Test

Displays for total consumption wrap around at 999.999Wh (or VARh, VAh) due to the limited number of avail-
able display digits. Internal registers (counters) of the Demo Code are 64 bits wide and do not wrap around.