Interlogix NS3500-28T-4S User Manual User Manual

Page 119

background image

119

Object

Description

Port Select

Select port number for this drop down list to set VLAN port setting.

Interface VLAN Mode

Set the port in access, trunk, hybrid, tunnel mode.

Trunk

means the port allows traffic of multiple VLAN.

Access

indicates the port belongs to one VLAN only.

Hybrid

means the port allows the traffic of multi-VLANs to pass with

tag or untag mode.

Tunnel

configures IEEE 802.1Q tunneling for a downlink port to

another device within the customer network.

PVID

Allow assign PVID for selected port.

The PVID will be inserted into all untagged frames entering the ingress port.

The PVID must as same as the VLAN ID that the port belong to VLAN group, or

the untagged traffic will be dropped.

The range for the PVID is 1-4094.

Accepted Type

Determines whether the port accepts all frames or only tagged frames. This

parameter affects VLAN ingress processing. If the port only accepts tagged

frames, untagged frames received on the port are discarded.

Options:

All

Tag Only

Untag Only

By default, the field is set to All.

Ingress Filtering

 If ingress filtering is enabled (checkbox is checked), frames classified to a

VLAN that the port is not a member of get discarded.

 If ingress filtering is disabled, frames classified to a VLAN that the port is not

a member of are accepted and forwarded to the switch engine.

However, the port will never transmit frames classified to VLANs that it is not a

member of.

Uplink

Enable/disable uplink function in trunk port.

TPID

Configure the type (TPID) of the protocol of switch trunk port.

Buttons

: Click to apply changes.