background image

Page 62

HV-WP/HW-WP Series

17.3. OP-04, Options

17.3.3. Command

List

The following explanation uses "Format 1 ( f15 3 )" assuming 23 as the address.

Data output

The current weighing data is output.

Template Q
Command

Reply

Selection of mode and unit

Selects the mode and unit. This is the same as the

MODE

switch.

Template U
Command

Reply

The scale changes mode and unit.

Zero

The current mass value is set to the zero point.

This is the same as the

ZERO

switch.

Template Z
Command

Reply

The mass value becomes zero and the zero point mark is displayed.

Tare

The current mass value becomes zero after placing a tare (receptacle, case, etc) and
the net is displayed. This is the same as the

TARE

switch.

Template T
Command

Reply

The current mass value becomes zero and the net mark is displayed.

Cancel of tare

The display value becomes the gross and the net mark is turned off. (The tare value
becomes zero.)

Template CT
Command

Reply

Gross is displayed and the net mark is turned off.

Preset tare

The tare value is set and the net value is displayed. The set value is a 5 digit
numerical value with a polarity sign and does not contain a decimal point.

Template PT,

[parameter]

Command

Reply

Net is displayed and the net mark is displayed.

Upper limit value

An upper limit value is stored.

The set value is a 5 digit numerical value with a polarity

sign and does not contain a decimal point.

Template HI,

[parameter]

Command

Reply

The upper limit value is stored.

Caution

The upper limit value must be greater than the lower limit value.