Page 27

10. Accumulation Function

Function table

Meaning and purpose

A

f8 4

When the display is a stable value and without nearly-zero, the
scale accumulates the data automatically. The next accumulation
can be performed after the display is nearly-zero.
Use

Recording the number and mass of articles removed from
the weighing pan. (Put the articles on the weighing pan.
Press the

TARE

switch at each removal.)

A
A
A
A
A
A

f8 5

At each finish of the full/dribble batch function, the scale accumulates
the data automatically.
Use

Packaging articles like a powder, it is used for recording the
bag number and total mass.

A
A
A


10.1. Preparation (Setting Parameters)

Step 1 Turn off the display.

Press

the

ON/OFF

switch while the

ZERO

switch is

pressed and held. The function table is displayed.




Step 2 Press the

ENTER

switch to display an item of the

accumulation function (

f8

).




Step 3 Select a parameter of the accumulation function

(

f8 1

~

f8 4

) with the

switch.



Step 4 Press the

ENTER

switch and the

F

switch to

display

end

. Press the

ENTER

switch to return

to the normal weighing mode.