Preparation (setting parameters), A a a – A&D Weighing HW-200KV-WP User Manual
Page 29
HV-WP/HW-WP Series
Page 27
10. Accumulation Function
Function table
Meaning and purpose
A
f8 4
When the display is a stable value and without nearly-zero, the
scale accumulates the data automatically. The next accumulation
can be performed after the display is nearly-zero.
Use
Recording the number and mass of articles removed from
the weighing pan. (Put the articles on the weighing pan.
Press the
TARE
switch at each removal.)
A
A
A
A
A
A
f8 5
At each finish of the full/dribble batch function, the scale accumulates
the data automatically.
Use
Packaging articles like a powder, it is used for recording the
bag number and total mass.
A
A
A
10.1. Preparation (Setting Parameters)
Step 1 Turn off the display.
Press
the
ON/OFF
switch while the
ZERO
switch is
pressed and held. The function table is displayed.
Step 2 Press the
ENTER
switch to display an item of the
accumulation function (
f8
).
Step 3 Select a parameter of the accumulation function
(
f8 1
~
f8 4
) with the
∧
switch.
Step 4 Press the
ENTER
switch and the
F
switch to
display
end
. Press the
ENTER
switch to return
to the normal weighing mode.