beautypg.com

A&D Weighing HW-200KV-WP User Manual

Page 49

background image

HV-WP/HW-WP Series

Page 47

15. The Function Table

Item

Display

Meaning and purpose

f9

Not used

The details of the full/dribble batch function (f6 9)

f10 0 #

Reaching final value and pressing the

F

switch, the current

process is finished.

A
A

f10 1

Reaching final value and displaying the stability mark, the current
process is finished automatically.

A
A

f10 2

Pressing the

SET

switch, the scale automatically tares and starts

the full/dribble batch process. Reaching final value and pressing

t

he

F

switch, the current process is finished.

A
A
A

Full/Dribble
batch
sub-func-ti
on

f10 3

Pressing the

SET

switch, the scale automatically tares and starts

the full/dribble batch process. Reaching final value and
displaying the stability mark, the current process is finished.

A
A
A

Address for RS-422 / RS-485 for option OP-04

f11 00#

Address

f11 01

f11 99

Use This address can be set from 01 to 99. It is possible for a

computer to control the scale assigned an address.

(RS-232C should be set to "00".)



The function to hold the current display value. When the value
becomes nearly-zero or the weighing value changes more than
25% +30 digits, hold display is canceled.



f12 0 # Not used

f12 1

The hold function is ON or OFF alternately by the

F

switch.

Hold

f12 2

Displaying the stability mark, the display is held.

Selects readability and response.

f13 0 # Fast response, sensitive value

f13 1

Ú

Averaging

f13 2

Slow response, stable value

Selects a storable minimum unit mass in the counting mode.

f14 0 # Stores a unit mass in the unit of a digit.

f14 1

Stores a unit mass in the unit of one eighth digit.

Precision
of unit
mass

f14 2

Stores a unit mass, if the total of the sample mass is greater than
5 digits.


Refer to "16.1. Data Format".

f15 0 # Format 1. (A&D general format for scales, balances)

f15 1 Format 2. (Older HV-A/ HW-A format)

f15 2

Not used

Format

f15 3

Format 1 (Return command is available for all commands.)

f16

Not used.

f17

The function number “f17” is not displayed.
When displaying 000000, press the

ENTER

switch to cancel.

The "#" is factory settings

The "nearly-zero" is within ±5 digits from zero point in the unit of kg.

The "digit", a unit of display, is equivalent to the minimum measurable mass.

This manual is related to the following products: