Outline and features – A&D Weighing HW-200KV-WP User Manual
Page 6
Page 4
HV-WP/HW-WP Series
2. Outline and Features
2. Outline and Features
These scales are designed to comply with IP-65 of IEC 529
The HV-WP series is a platform scale with 1/3000 resolution, and has a "triple
weighing range" function to select the weighing range.
The HW-WP series is a platform scale with 1/10000 resolution.
The scales have a fluorescent display so the weighing value can be read in dim light.
This type uses the AC power line as a power source.
Using the standard RS-232C serial interface, data can be output to a printer, and the
scale can be controlled or can be set by a command from a personal computer.
The counting mode function converts the total mass value (total weight) of articles to
be counted, to a count, when each of these articles assume the same mass value.
The scales can display the unit of percentage.
The accumulation function accumulates each weighing value and counts the number
of weighings using six figures.
The comparator function compares the display value with the upper limit value (HI),
lower limit value (LO) and displays the result. The result can be output by a buzzer if
option OP-03 is installed.
The simple batch function or full/dribble batch function can be used for filling up to a
target mass value. The status of a weighing value can be output if option OP-03 or
OP-04 is installed. The outputs are zero band, preliminary and final.
Using the optional RS-422/RS-485 serial interface and a computer, up to 16 scales
can be controled, if this option (OP-04) is installed in place of the RS-232C serial
interface.
The following parameters are stored in the product with no power supplied.
Unit mass of the counting mode
100% mass of the percentage mode
Total count and total mass of the accumulation function
Upper limit value and lower limit value of the upper / lower comparator function,
Final value, preliminary value and zero band of the full / dribble batch function or
Final value, preliminary value and zero band of the simple batch function
Calibration data
Parameters of the function table (f1 ~ f17)