A&D Weighing GF-32K User Manual
Page 61
59
Recalling the memory data
Confirm that the "Data memory (
data
)" parameter is set to "
2
".
Step 1 Press and hold the
key until
reCall
is displayed,
then release the key.
Step 2 Press the
key to enter the memory recall mode. The
type of data appears in the upper left of the display as shown to
the right. Recall the data in memory using the following keys.
RE-ZERO
key .. To proceed to the next data set.
MODE
key ...... To go back to the previous data set.
key ...... To transmit the current data using the RS-232C interface.
With
SAMPLE
held down, press the
CAL
key
To delete the current data.
Note Deleting the data will not increase the number of data that can be stored.
CAL
key ......... To exit the memory recall mode.
Step 3 Press
the
CAL
key to return to the weighing mode.
Transmitting all memory data at one time
Confirm that the "Serial interface (
5if
)" parameters are set properly.
Refer to "10. Function Table" and "16-2. Connection To Peripheral
Equipment".
Step 1 Press and hold the
key until
reCall
is displayed,
then release the key.
Step 2 Press
the
SAMPLE
key to display
out
.
Step 3 Press
the
key to display
out "n"o
with "no" blinking.
Step 5 Press
the
RE-ZERO
key to display
out "g"o
with "go" blinking.
Step 6 Press
the
key to transmit all data using the RS-232C interface.
Step 7 The balance displays
Clear
when all data is transmitted.
Press the
CAL
key to return to the weighing mode.
Deleting all memory data at one time
Step 1 Press and hold the
key until
reCall
is displayed, then release the key.
Step 2 Press the
SAMPLE
key several times to display
Clear
.
Step 3 Press the
key to display
Clr "n"o
with "no" blinking.
Step 4 Press the
RE-ZERO
key to display
Clr "g"o
with "go" blinking.
Step 5 Press the
key to delete all data
Step 6 The balance displays
end
when all data is deleted.
The balance displays
reCall
.
Step 7 Press the
CAL
key to return to the weighing mode.
Indicators
Weighing data
without time and date
Weighing data with
time and date
Indicators
Weighing data
without time and date
Weighing data with
time and date