Installation

• The SL-CHG must be installed only after securing the minimum safety distance between the SL-CHG

and the hazardous zone or hazard as established by the applicable regulations of the country or region
in which the SL-CHG is being used.

• Choose locations for the installation of SL-CHG transmitters and receivers so that they are not subject

to the effects of light reflected from glossy surfaces in the area.

• Use the same models (same beam axis) for transmitter/receiver pairs.
• The SL-CHG must be installed in such a way that machine operators cannot reach the hazardous

zones or hazards of the machine without passing through the SL-CHG's detection zone. Strictly avoid
installations which allow machine operators to access the area between the SL-CHG and the machine,
or where machine operators can approach the machine's hazardous zones, without passing through the
SL-CHG's detection zone.

• Always perform tests after installing the SL-CHG in accordance with the test procedures established in

this instruction manual, verifying that the test pieces are detected in all of the detection zones.

• When the Intelligent Extension Unit (SL-R12EX) is used to enable the fixed blanking function, additional

safety measures must be implemented for the zone in which that function is enabled so that it is impos-
sible to reach the hazardous zone or hazards of the machine by passing through that zone.

• When the Intelligent Extension Unit (SL-R12EX) is used to enable the floating blanking function, the

minimum safety distance will be affected due to the fact that the function has a negative effect on the
detection capability. Therefore, in such cases, calculate the minimum safety distance using the new
value for detection capability with the floating blanking function enabled and apply the result for the SL-
CHG installation.

• When the Intelligent Extension Unit (SL-R12EX) is used to enable the floating blanking function, confirm

that the actual number of beam axes with which the floating blanking function is active matches the
number of beam axes specified in the floating blanking function setting.

• When the Blanking Blind Protection Unit (SL-C08SB/SL-C16SB) is used to install the SL-CHG, a test

must be carried out according to the procedures described in this instruction manual to confirm that the
test piece can be detected in all detection zones including the detection zone that can be detected by
the Blanking Blind Protection Unit.

• Securely tighten mounting brackets and cord (cable) connectors used in the installation of the SL-CHG

in accordance with the torque values established in this instruction manual.

4. Circuit Design and Wiring

Always turn off the device power when performing electrical wiring.

Follow electrical standards and regulations for the country or region in which the SL-CHG is being used
when performing the electrical wiring. Only qualified persons should perform wiring.

Do not place any cables or electrical lines used in wiring the SL-CHG in the same duct as high-voltage
electrical or power lines or in parallel with such lines.

When the SL-CHG Series is used as a safety device on press machinery operated inside Japan, the
protective sheathing included with the cables must be installed.

Do not extend transmitter and receiver cables over a maximum distance of 30 meters (98.43 ft.).

Install the mechanism used to reset the interlock (switches, etc.) in a position from which the condition of
the entire hazardous zone can be checked. Do not install the reset mechanism in a position where it can
be operated within the hazardous zone.

The control outputs (OSSD for SL-CHG Series or FSD for SL-R11G) of the two systems provided in the
SL-CHG must both be used to build a safety system. Building a safety system with just one of these
systems cannot stop the machine due to a control output malfunction and can result in a serious accident,
including serious injury or death to the machine operator.

5. Testing and Maintenance

Always perform testing in accordance with the test procedures after maintenance, adjustment, or calibra-
tion of the target machine or the SL-CHG, and before the machine start-up.

If the SL-CHG does not operate properly when tested in accordance with the test procedures established
in this instruction manual, do not operate the machine.

Periodically examine the machine to verify that all brakes, other stop mechanisms, and control devices
operate reliably and accurately in addition to checking the SL-CHG.

The responsible personnel must perform maintenance procedures as established in this instruction
manual at least once every six months to ensure safe device operation.