Chapter 4 Checklist
4-2
4
English
ENGLISH
3. Check Using an Operation Test with the Machine Stopped
With the machine stopped, turn on the power of the SL-CHG and carry out the following tests using
the test piece included in the package. If the floating blanking function is active, do not use the at-
tached test piece, but use a proper test piece that conforms to the description given in the SL-R12EX
manual.
❏
The output status indicator (bar LED) on the SL-CHG turns red and stays red while the test piece is
present within the detection zone.
❏
When the power of the SL-CHG is turned on with no test piece in the detection zone, the output
status indicator as well as all eight bar LEDs turn green.
❏
The test piece can be detected regardless of its location as long as it is in the detection zone.
❏
If the SL-R11G restart interlock function is enabled, when the test piece is removed, confirm that
bar LEDs on the SL-CHG light up green, the output status indicator lights up red, and the SL-R11G
interlock indicator lights up yellow.
❏
When in the restart interlock state, the start/restart input causes the output status indicator to
change to green, and the SL-R11G interlock indicator to turn off.
❏
If the SL-R11G start interlock function is enabled, confirm that the bar LEDs light up green, the
output status indicator turns red, and the SL-R11G interlock indicator lights up yellow when the
power of the SL-CHG is turned on with no object in the detection zone.
❏
In addition, the output status indicator changes to green and the SL-R11G interlock indicator turns
off when there is a start/restart input while in the start interlock state.
Move the test piece for detection confirmation as illustrated in the figure below.
Star
t
Stop
4. Operation Test with the Machine Operating
This test confirms that the machine stops its operation.
❏
Place the test piece in the detection zone or protection zone of the SL-CHG. It is recommended to
try three locations: near the transmitter, near the receiver, and the central area of the detection
zone. The machine must stop by the detection of the test piece.
❏
The machine must remain stopped as long as the test piece is in the detection zone.
❏
The machine will not operate when the SL-CHG Series power supply has been interrupted.
❏
The overall response time of the machine, including the response time of the SL-CHG and the time
it takes for the machine to stop, must be shorter than the overall response time T used in the
calculation of safety distances (
See “2-2 Safety Distances” (
➮page 2-4)).