Checking the packed items – KEYENCE GP-M Series User Manual

Page 6

background image

6

4. Do not remove the seal of the air hole of the

GP-M001/M010/M025. It will no longer be

waterproof.

5. When condensation occurs, it may become

impossible to make measurements, or,

damage may occur. Take measures such as

the following to prevent condensation.

• Ensure that the ambient temperature is the same

or lower than the fluid temperature.

• Remove moisture via air conditioning
• Separate the sensor 30 cm or more from the

cooling pipes using the connector pipe.

6. When conducting maintenance, use a soft

brush so as not to damage items such as the

detection surface or the O-Ring.

7. When replacing the O-Ring, clean all of the

debris from the surface that will be in contact

with the O-Ring.

Checking the Packed Items

GP-M001/M010/M025

Sensor x 1

Instruction manual x 1

O-Ring x 1

(OP-87287)

GP-M100/M250/M400

Sensor x 1

Instruction manual x 1

O-Ring set x 1

(OP-87288)

NOTICE