Offset correction, Delay timer – KEYENCE GP-M Series User Manual
Page 19

19
Offset correction
Concerning the value at the time of
shipping, there may be as much
as ±10%F.S. offset correction.
This activates in the case of a
margin of error in the displayed
pressure value and the actual
pressure value.
The pressure value after the offset
correction is displayed on the
setting screen and can be adjusted with the UV buttons.
Delay timer
The delay timer can be set within the range of 0.00 to 50.00(s)
When the function selection of output 2 is out (control output) the
delay timer for output 1 and output 2 can be set separately.
* The setting of the dS2, dr2 is possible when the function of output 2 is
selected as out (control output).
• Offset correction works in conjunction with “Atmospheric
pressure correction”.
• If the UV buttons are pressed and held simultaneously
on the offset correction screen, the offset correction
value and the air pressure correction value will revert to
the condition at shipping (no correction).
Setting
item
Meaning
F5
/F5 Concerning the ON delay timer of output 1/output 2. When the
judgment switches from OFF to ON, the set delay time will elapse.
FT
/FT Concerning the OFF delay time of output 1/output 2. When the
judgment switches from ON to OFF, the set delay time will elapse.
Pressure value
±10%F.S.
Display value
Solid line:
condition at shipping
Reference