Initialization value list – KEYENCE GP-M Series User Manual

Page 14

background image

14

Pressing

and

U

at the same time will return to the

previous screen.

Initialization Value List

Item

Default value (by model)

Model

GP-M

001

GP-M

010

GP-M

025

GP-M

100

GP-M

250

GP-M

400

Unit

kPa

MPa

SP1/FH1

(Switch-on point 1)

40.0

0.400 1.000

4.00

10.00 16.00

rP1/FL1

(Switch-off point 1)

20.0

0.200 0.500

2.00

5.00

8.00

SP2/FH2

(Switch-on point 2)

100.0 1.000 2.500 10.00 25.00 40.00

rP2/FL2

(Switch-off point 2)

80.0

0.800 2.000

8.00

20.00 32.00

ASP (Analog start

point (4 mA))

-100.0 0.000 0.000

0.00

0.00

0.00

AEP (Analog end

point (20 mA))

100.0 1.000 2.500 10.00 25.00 40.00

Item

Default value (for all models)

ou1 (detection mode of output 1)

Hno

ou2 (detection mode of output 2)

Hno

CoF (offset correction)

No correction

dS1/dr1/dS2/dr2 (direct timer)

0.00 (s)

SPEd (responsiveness)

3 (ms)

Eco (power-save mode)

oFF

HYS (presence of hysterisis when in window mode)

on

diS.U (display renew cycle)

200 (ms)

diS.r (display inversion)

no

PASS (password)

0000

Reference

MODE