KEYENCE LJ-H1W User Manual
Page 41

View Measurement Value
4-3
Di
s
pl
a
ying the
Me
asu
rement D
a
ta
4
LJ-H1W-M-NO4-E
(3)Measurement control
Inputs a control signal into the connected controller.
Reference
For more information about each control signal, see
"LJ-G Series User's Manual".
(4)[Close] button
Closes the [View measurement value] window.
(5)[Help] button
Opens the help function for LJ-Navigator.
[Trigger] button
Inputs a trigger to the specified head.
: When inputting a trigger to only Head A
: When inputting a trigger to only Head B
: When inputting a trigger to both Head A and Head B
[TIMING] button
Inputs a TIMING input to the specified TIM.
Assign the TIMING input for each OUT setting by using the [Common] tab.
: When inputting TIMING on only TIM1
: When inputting TIMING on only TIM2
: When inputting TIMING on both TIM1 and TIM2
[ZERO] button
Inputs an auto-zero for the specified ZERO.
Assign the ZERO input for each OUT setting by using the [Common] tab.
: When inputting auto-zero on only ZERO1
: When inputting auto-zero on only ZERO2
: When inputting auto-zero on both ZERO1 and ZERO2
[Reset] button
Resets the measured values that are displayed.