DP-V1 Service
3-32
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT-70A) -
Execu
ting Communi
cat
ion
3
*1 The error content of the sensor amplifier can be checked by noting the ON/OFF
state of each bit.
OFF (0): No error; ON (1): Error
More than one error may occur simultaneously. For details of each error, refer to the
GT-70A Series User's Manual.
*2 Details of output status can be checked by noting the ON/OFF state of each bit.
*3 If the judgment value is correct, the parameter range is -199.999 to +199.999.
When the comparator value is over range, "+999.999" is stored.
When the comparator value is under range, "-999.999" is stored.
When the comparator value is invalid, "-999.998" is stored.
When an error occurs, "+1000.000" is stored.
*4 When you use the calculation function and calculation setting is set to other than
standard difference display, a reading error occurs on the expansion unit.
When the calculation setting is set to standard difference display, a reading error
occurs on the main unit.
*5 This parameter can be used only when the detection mode of the sensor amplifier is peak-to-
peak hold. A reading error occurs when the mode is set to other than peak-to-peak hold.
This parameter may be used for judging the outer diameter of cylinders, in order to
read the peak and bottom values during measurement.
*6 When you do not use the calculation function, a reading error occurs.
*7 This parameter cannot be written when the key lock function is used.
*8 This parameter can be written only if the sensor amplifier meets the two conditions:
•
The timing type parameter is set to "external timing."
•
The input (pink/purple wire) function selection 2 parameter is set to "Change bank
B."
*9 These parameters can be read/written to only the main unit (ID: 01) of sensor amplifiers.
*10 These parameters are available only when the calculation function is used.
192
Group6 Entry count
DINT
R
193
Product code
DINT
R
Main unit:=4006
Expansion unit:=4007
194 to
199
Reserved for system
200
Product name 1
*11
DINT/
STRING
R
-
Main unit:=”GT-7”
Expansion unit:=”GT-7”
201
Product name 2
*11
DINT/
STRING
R
-
Main unit:="1A*/"
Expansion unit:="2A*/"
202
Product name 3
*11
DINT/
STRING
R
Main unit:="75A*"
Expansion unit:="76A*"
203
Product name 4
*11
DINT/
STRING
R
Main unit:=""
Expansion unit:=""
204 to
217
Reserved for system
218
Unit
219 to
223
Reserved for system
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value