3
GT-70A series index (Slot 1 to 10)
Attribute R: Read; W: Write; R/W: Read/Write; C: Motion command
The data types are DINT (32-bit signed integer).
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value
0
Group0 Entry count
DINT
R
5
1
Preset request
DINT
C
2
Preset reset request
DINT
C
3
Reset request
DINT
C
4
Error clear
DINT
C
5
Initialize request
DINT
C
6 to 31
Reserved for system
32
Group1 Entry Count
DINT
R
9
33
Sensor amplifier error state
*1
DINT
R
-
Bit0: Overcurrent error (ErC)
Bit1: Head error (ErH)
Bit2: EEPROM error (ErE)
Bit3: Jam check error (Er.chK)
Bit4: Self-timing delay error
(Er.dLY)
Bit5: Number-of-units error
(Er.Unit)
Bit6: Calculation error (Er.CAL)
34 to 35 Reserved for system
36
Control output
*2
DINT
R
Bit0: HIGH
Bit1: LOW
Bit2: GO
37
Comparator value (P.V. value)
*3
*4
DINT
R
38
Raw value (R.V. value)
*3
DINT
R
39
Peak value during sampling
*3
*4
*5
DINT
R
40
Bottom value during sampling
DINT
R
41
Calculation display value
*3
*6
DINT
R
42 to 63 Reserved for system
64
Group2 Entry count
DINT
R
12
65
Bank 0 HIGH setting
DINT
R/W
+005.0000
-099.999 to +999.999
66
Bank 0 LOW setting
DINT
R/W
+002.0000
-099.999 to +999.999
67
Bank 0 preset value
DINT
R/W
000.0000
-099.999 to +999.999
68
Bank 1 HIGH setting
DINT
R/W
+005.0000
-099.999 to +999.999
69
Bank 1 LOW setting
DINT
R/W
+002.0000
-099.999 to +999.999
70
Bank 1 preset value
DINT
R/W
000.0000
-099.999 to +999.999
71
Bank 2 HIGH setting
DINT
R/W
+005.0000
-099.999 to +999.999
72
Bank 2 LOW setting
DINT
R/W
+002.0000
-099.999 to +999.999
73
Bank 2 preset value
DINT
R/W
000.0000
-099.999 to +999.999
74
Bank 3 HIGH setting
DINT
R/W
+005.0000
-099.999 to +999.999
75
Bank 3 LOW setting
DINT
R/W
+002.0000
-099.999 to +999.999
76
Bank 3 preset value
DINT
R/W
000.0000
-099.999 to +999.999
77 to 95 Reserved for system
96
Group3 Entry Count
DINT
R
7