4 diagnostic function, Execu ting communi cat ion, Module status in the state as shown on the left – KEYENCE DL-PD1 User Manual
Page 36

3-4
Diagnostic Function
3-14
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT-70A) -
Execu
ting Communi
cat
ion
3
Example)
15
Slot 0 module status
0
00
B
: Normal
01
B
: System error
10
B
: The unit on the configuration
does not match the unit
actually connected.
11
B
: The unit is connected despite
the unit is not assigned on the
configuration, or the unit is not
connected despite the unit is
assigned on the configuration.
1
Slot 1 module status
2
3
Slot 2 module status
4
5
Slot 3 module status
6
7
16
Slot 4 module status
0
1
:
:
Slot 7 module status
6
7
17
Slot 8 module status
0
1
:
:
Slot 11 module status
6
7
18
Slot 12 module status
0
1
:
:
Slot 15 module status
6
7
19
Reserved for system
0
:
7
0000
B
(fixed)
Octet
Content
bit
Value
DL-PD1
DL-PD1
GT-71A
GT-72A
GT-72A
IL-1050
1
0
2 3 4
GT-71A
GT-72A
IL-1050
1
0
2 3
Configuration on the
configuration software
Module status in the state as shown on
the left
Byte
Value
10
00 00 10 01
B
11
10 00 00 10
B
12
00 00 00 00
B
13
00 00 00 00
B
14
10 00 00 00
B
3
2
1
0
Slot number
15
00 00 00
11
B
7
6
5
4
Slot number
:
:
Slot number
Slot number
Actual configuration