beautypg.com

General specifications, Connecting the profibus -6, 3 technical data – KEYENCE DL-PD1 User Manual

Page 22: Con nect io n a nd co nf igu ra tion

background image

2-3

Technical data

2-8

- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT-70A) -

Con

nect

io

n a
nd
Co
nf

igu
ra

tion

2

General Specifications

*1 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.
*2 Varies with the sensor amplifiers connected.

Model

DL-PD1

PROFIBUS DP
specifications

Device type

DP-V1 Slave (D-sub 9 pin, Number of the ports: 1)

Communication speed

9.6 kbit/s to 12 Mbit/s

Cable length

9.6 / 19.2 / 45.45 / 93.75 kbit/s: 1200 m
187.5 kbit/s: 1000 m
500 kbit/s: 400 m
1.5 Mbit/s: 200 m
3 / 6 / 12 Mbit/s: 100 m

Sensor amplifier
connection
specifications

Connectable sensor
amplifiers

Sensor amplifiers with D-bus support

*1

Number of connectable
sensor amplifier units

15 units max.

*2

Power voltage

20 to 30 VDC, including ripple (p-p) 10%
(This voltage is supplied from the connected sensor amplifier.)

Power consumption

1600 mW or less (65 mA max. at 24 V)

Environmental
resistance

Operating surrounding
air temperature

-20 to +55°C (no freezing)

Operating surrounding
air humidity

35 to 85% RH (no condensation)

Vibration resistance

IEC60068-2-6 2G (10 to 500 Hz, 2 hours each in X, Y, Z direction)

Impact resistance

IEC60068-2-27 30G (11 ms, 3 times each in X, Y, Z direction)

Materials

Main unit case and dust cover: Polycarbonate
PROFIBUS connector: Steel - Nickel plating

Weight (including connectors)

Approx. 65 g