3-3
Parameterization
Set parameters on the configuration software of PROFIBUS DP.
Set as necessary.
Standard parameter
Parameters specified by PROFIBUS DP/DPV1 standard
Octet
Name
Description
Value
1
Station Status
Station status
BIT2-0: reserved
BIT3: Watchdog on
BIT4: Freeze mode request
BIT5: Sync mode request
BIT6: Unlock request
BIT7: Lock request
2
WD_Fact_1
Watchdog element 1
-
3
WD_Fact_2
Watchdog element 2
-
4
TSDR
Shortest TSDR time
-
5
Ident number (H)
Manufacturer code (high byte)
0D
H
6
Ident number (L)
Manufacturer code (low byte)
FD
H
7
Group ID
Group assignment for broadcast and
multi cast (SYNC,FREEZE, CLEAR)
-
8
DPV1 Status1
DPV1 status 1 (See EN50170.)
BIT1-0: reserved
BIT2: Watchdog time base 1 ms
BIT4-3: reserved
BIT5: 0 (fixed)
BIT6: Fail_safe
BIT7: DP-V1_Enable
(Default value: 1100 0000
B
)
9
DPV1 Status2
DPV1 status 2 (See EN50170.)
BIT0: Check_Cfg_Mode
BIT1: reserved
BIT7-2: 0 (fixed)
(Default value: 0000 0001
B
)
10
DPV1 Status3
DPV1 status 3 (See EN50170.)
0 (fixed)