6 dp-v1 service, Execu ting communi cat ion – KEYENCE DL-PD1 User Manual
Page 53

3-6
DP-V1 Service
3-31
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT-70A) -
Execu
ting Communi
cat
ion
3
139
Measurement direction
DINT
R/W
0
0: Normal
1: Reverse
140
Multiplier
DINT
R/W
001.0
000.1 to 100.0
141
Output mode
DINT
R/W
0
0: NO
1: NC
142
Display resolution
DINT
R/W
0
0: 0.0001
1: 0.001
2: 0.01
3: 0.1
143
Hysteresis
DINT
R/W
+000.003
000.000 to +999.999
144
Input (purple wire) func. 1
DINT
R/W
0
0: Bank A
1: Reset
145
Input (pink/purple wire) func.
2
DINT
R/W
0
0: Timing input
1: Bank B
146 to
148
Reserved for system
149
Preset memory
DINT
R/W
0
0: YES
1: NO
150
Reserved for system
151
Power-saving function (ECO)
DINT
W
0
0: OFF
1: HALF
2: ALL
152
Jam detection function
DINT
R/W
0
0: OFF
1: ON
2: USER
153
Check point setting
DINT
R/W
+000.500
-65.534 to +65.534
154
Display filter function
DINT
R/W
0
0: ON
1: OFF
155 to
159
Reserved for system
160
Group5 Entry count
DINT
R
10
161
R.V. (base of calc.) ID01
*3
*10
DINT
R
162
R.V. (base of calc.) ID02
*3
*10
DINT
R
163
R.V. (base of calc.) ID03
*3
*10
DINT
R
164
R.V. (base of calc.) ID04
*3
*10
DINT
R
165
R.V. (base of calc.) ID05
*3
*10
DINT
R
166
R.V. (base of calc.) ID06
*3
*10
DINT
R
167
R.V. (base of calc.) ID07
*3
*10
DINT
R
168
R.V. (base of calc.) ID08
*3
*10
DINT
R
169
R.V. (base of calc.) ID09
*3
*10
DINT
R
170
R.V. (base of calc.) ID10
*3
*10
DINT
R
171 to
191
Reserved for system
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value