4 message communication 3-38, Com m uni ca tin g w ith fd -m h se ries – KEYENCE DL-EP1 User Manual
Page 66

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -
3-4 Message Communication
3-38
3
C
om
m
uni
ca
tin
g
w
ith FD
-M
H
Se
ries
Group2
0343H
(835)
Temperature
upper limit
setting value
*8
Indicates the temperature upper limit setting
value.
Parameter range:
0.1 to 99.9: Upper limit value (initial value: 80.0)
100.0: Upper limit detection invalid
R/W
DINT
0344H
(836)
Temperature
lower limit
setting value
*9
Indicates the temperature lower limit setting
value.
Parameter range:
0.1 to 99.9: Lower limit value (initial value: 5.0)
0.0: Lower limit detection invalid
R/W
DINT
0345H
(837)
Integrated
flow rate
setting value
1
Indicates the integrated flow rate setting value
1.
The value obtained by multiplying this value by
the value set in integrated flow rate units serves
as the actual integrated flow rate setting value.
Parameter range: 0 to 9999 (initial value: 150)
R/W
DINT
0346H
(838)
Integrated
flow rate
setting value
2
Indicates the integrated flow rate setting value
2.
The value obtained by multiplying this value by
the value set in integrated flow rate units serves
as the actual integrated flow rate setting value.
Parameter range: 0 to 9999 (initial value: 9999)
R/W
DINT
0347H
(839)
Instantaneous
flow rate
setting value
3 (P3)
*7
Indicates the instantaneous flow rate setting
value 3 (P3).
Parameter range:
FD-MH10A: 0.00 to 30.00 (initial value: 13.00)
FD-MH50A: 0.0 to 100.0 (initial value: 65.0)
FD-MH100A: 0.0 to 200.0 (initial value: 130.0)
FD-MH500A: 0.0 to 999.9 (initial value: 400.0)
R/W
DINT
0348H
(840)
Instantaneous
flow rate
setting value
4 (P4)
*7
Indicates the instantaneous flow rate setting
value 4 (P4).
Parameter range:
FD-MH10A: 0.00 to 30.00 (initial value: 20.00)
FD-MH50A: 0.0 to 100.0 (initial value: 100.0)
FD-MH100A: 0.0 to 200.0 (initial value: 200.0)
FD-MH500A: 0.0 to 999.9 (initial value: 500.0)
R/W
DINT
0349H
(841) to
035FH
(863)
(Reserved for system)
Group3
0360H
(864)
Group3 Entry
count
Indicates the group 3 entry count.
Parameter range: 5
R
DINT
0361H
(865)
Key lock
function
Indicates the key lock function.
Parameter range: 0 to 1
0: Key unlock (initial value)
1: Key lock
R/W
DINT
0362H
(866)
(Reserved for system)
0363H
(867)
Analog output
selection
*10
Indicates the analog output selection.
Parameter range: 0 to 1
0: Standard (initial value)
1: Free range analog
R/W
DINT
Class
Attribute
ID
Name
Description
Attribute
Data
Type