beautypg.com

Dl object (class id:67h), Dl object (class id:67h) -31 – KEYENCE DL-EP1 User Manual

Page 59

background image

3-4 Message Communication

3-31

3

C

om
m

uni

ca

tin

g

w

ith FD

-M

H

Se
ries

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -

The DL Object provides the DL-EP1 connection status and device write/read. This
object is unique to the DL-EP1.

Services

*1 This service cannot be used in the DL-EP1 (instance ID:00H).

*2 This service cannot be used in the sensor amplifier (instance ID: 01H to 0AH)

connected to the DL-EP1.

*3 In the DL-EP1 (instance ID: 00H), this service can be used as the attribute ID

90H to 9EH and A0H to AEH.

DL Object (Class ID:67H)

Service

Code

Service Name

Description

0EH

Parameter

read

Reads parameters from the DL-EP1 and the sensor amplifier
connected to the DL-EP1. For examples of using this service,
refer to

"(1) Reading parameters from a sensor amplifier"

(Page 3-43).

10H

Parameter

write

Writes parameters to the DL-EP1 and the sensor amplifier
connected to the DL-EP1. For examples of using this service,
refer to

"(2) Writing parameters to a sensor amplifier"

(Page 3-44).

4BH

*1

Operation

command

Requests processing such as zero shift and tuning from the
sensor amplifier connected to the DL-EP1. The contents of
processing that can be requested differ per sensor amplifier.
Set the contents of processing with the attribute ID in the
object.
refer to

"Attribute IDs supported by the instance service

4BH (operation command)" (Page 3-45). For examples of
using this service, refer to

"(3) Issuing operation commands to a sensor amplifier"

(Page 3-45).

4CH

Batch lock

setting

*2

Collectively performs lock or unlock for all the connected
sensor amplifiers. Even if a lock setting that is not supported
by sensor amplifiers is designated, locks all the sensor
amplifiers without interrupting processing. Then, error code
09H is returned as a response.
Setting 0: Not lock
Setting 1: Key lock

"Lock setting" (Page 3-32)

For examples of using this service, refer to

"(4) Locking

sensor amplifier operations" (Page 3-47).

4DH

Acquisition of the

number of decimal

places

*3

Acquires the number of decimal places of the designated
parameter. For examples of using this service, refer to

"(5)

Reading the number of decimal places in the parameter from
a sensor amplifier" (Page 3-48)
.