KEYENCE DL-EP1 User Manual
Page 106
5-5 Objects Usable by DL-EP1
5-26
Connection Manager Object
5
App
end
ix
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -
*1
Forward_Open is successful if the size you are trying to open is less than the
size defined in the scan list. If this error occurs, an extended status is added
and the data size of the tag defined in the second extended status is returned.
*2
RPI is set in increments of 500 μs. If a value that cannot be divided by 500 μs is
set, an RPI rounded to the nearest 500 μs is designated.
Forward_
Open
01H
0315H
• Connection Size of the ForwardOpen network connection
parameter is 0.
• Connection Path of ForwardOpen does not include
ConnectionPoint.
• In Connection Path class ID of ForwardOpen, a value other
than 0x04 was set as cyclic or a value other than 02H was
set as Class 3.
• In Class3, a value other than 1 is set as the instance ID of
Connection Path of ForwardOpen.
• There is a setting unique to the product (data segment).
• In cyclic communication, an invalid Connection Point is
designated in the send direction of Connection Path of
ForwardOpen.
• In cyclic communication, a value other than 2 is
designated as the Connection Size network connection
parameter in the send direction of ForwardOpen.
• In cyclic communication, an invalid Connection Point is
designated in the receive direction of Connection Path of
ForwardOpen.
0322H
An error occurred when the DL-EP1 was reinitializing
communication or when it was communicating with a sensor
amplifier.
0323H
An unsupported sensor was connected.
0324H
The connected sensors are in an unmixable combination.
0326H
Too many sensors are connected.
04C2H
A product-unique setting error occurred.
0640H-067FH The appropriate device is not connected or an error occurred
during communication between sensors.
06C0H-06FFH The number of occupied slots is different
0700H-073FH When "Check Model Match" is selected as compatibility
check, ProductCodes do not match.
0740H-077FH When "Check Model Match" is selected as compatibility
check, the major revisions or minor revisions do not match.
0780H-07BFH When "Check Series" is selected as compatibility check, the
series codes do not match.
07C0H-07FFH
When "Check Series" is selected as compatibility check, the
series version of the real machine is lower than the set
series version.
02H
-
The maximum number of connections have already been
used.
04H
-
The attribute ID is already designated.
05H
-
The designated instance ID does not exist.
13H
-
The length of send data is too short.
15H
-
The length of send data is too large.
Others
08H
-
The designated service is not supported.
Name
General
Status
Additional
(Extended)
Status
Description