4 message communication 3-37, Com m uni ca tin g w ith fd -m h se ries – KEYENCE DL-EP1 User Manual
Page 65

3-4 Message Communication
3-37
3
C
om
m
uni
ca
tin
g
w
ith FD
-M
H
Se
ries
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -
Group1
0329H
(809) to
032AH
(810)
(Reserved for system)
032BH
(811)
Bank
switching
status
Indicates the bank switching status.
Parameter range: 0 to 1
0: Bank A
1: Bank B
R
DINT
032CH
(812)
(Reserved for system)
032DH
(813)
Current
temperature
*5
Indicates the current temperature.
Parameter range: 0.0 to 999.9
R
DINT
032EH
(814)
Temperature
peak hold
value
*5
Indicates the temperature peak hold value.
Parameter range: 0.0 to 999.9
R
DINT
032FH
(815)
Temperature
peak hold
value
*5
Indicates the temperature bottom hold value.
Parameter range: 0.0 to 999.9
R
DINT
0330H
(816) to
0333H
(819)
(Reserved for system)
0334H
(820)
External input
status
Indicates the external input status.
Parameter range: 0 to 1
0:OFF
1:ON
R
DINT
0335H
(821)
(Reserved for system)
0336H
(822)
Temperature
sensor
connection
*6
Indicates the temperature sensor connection.
Parameter range: 0 to 1
0: Not connected
1: Connected
R
DINT
0337H
(823) to
033FH
(831)
(Reserved for system)
Group2
0340H
(832)
Group2 Entry
count
Indicates the group 2 entry count.
Parameter range: 8
R
DINT
0341H
(833)
Instantaneous
flow rate
setting value
1(P1)
*7
Indicates the instantaneous flow rate setting
value 1 (P1).
Parameter range:
FD-MH10A: 0.00 to 30.00 (initial value: 3.00)
FD-MH50A: 0.0 to 100.0 (initial value: 15.0)
FD-MH100A: 0.0 to 200.0 (initial value: 30.0)
FD-MH500A: 0.0 to 999.9 (initial value: 100.0)
R/W
DINT
0342H
(834)
Instantaneous
flow rate
setting value
2(P1)
*7
Indicates the instantaneous flow rate setting
value 2 (P2).
Parameter range:
FD-MH10A: 0.00 to 30.00 (initial value: 10.00)
FD-MH50A: 0.0 to 100.0 (initial value: 50.0)
FD-MH100A: 0.0 to 200.0 (initial value: 100.0)
FD-MH500A: 0.0 to 999.9 (initial value: 200.0)
R/W
DINT
Class
Attribute
ID
Name
Description
Attribute
Data
Type