4 message communication 3-36 – KEYENCE DL-EP1 User Manual
Page 64

- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -
3-4 Message Communication
3-36
3
C
om
m
uni
ca
tin
g
w
ith FD
-M
H
Se
ries
Attributes for FD-MH Series
Designate the ID number (01H to 0AH) of a sensor amplifier as the instance ID.
Class
Attribute
ID
Name
Description
Attribute
Data
Type
Group1
0320H
(800)
Group1
Entry count
Indicates the group 1 entry count.
Parameter range: 22
R
DINT
0321H
(801)
Sensor
amplifier
error state
*1
Indicates the error status of the sensor amplifier.
Bit 2 : Overcurrent error (ErC)
Bit 3 : EEPROM error (ErE)
Bit 4 : Fixed at 0
Bit 5 : Fixed at 0
Bit 6 : Backflow error (rEv)
Bit 8 : Temperature lower limit error
Bit 9 : Temperature upper limit error
Bit 10 : Temperature sensor connection error
(Err tEMP)
Other than the above: Fixed at 0
R
DWORD
0322H
(802) to
0323H
(803)
Reserved for system
0324H
(804)
Control output
Integration
pulse output
Abnormal
alarm output
status
*2
Indicates the control output.
Bit 0: Output 1
Bit 1: Output 2
Bit 2: Output 3
Other than the above: Fixed at 0
R
DWORD
0325H
(805)
Instantaneous
flow rate
(current
value)
*3
Indicates the instantaneous flow rate (current
value).
Parameter range:
FD-MH10A: 0.00 to 99.99
FD-MH50A: 0.0 to 999.9
FD-MH100A: 0.0 to 999.9
FD-MH500A: 0.0 to 9999.9
R
DINT
0326H
(806)
Integrated flow
rate
*4
Indicates the integrated flow rate.
Parameter range:
FD-MH10A: 0.00 to 4294967.29
FD-MH50A: 0.0 to 42949672.9
FD-MH100A: 0.0 to 42949672.9
FD-MH500A: 0 to 429496729
R
DINT
0327H
(807)
Instantaneous
flow rate
(peak hold
value)
*3
Indicates the instantaneous flow rate (peak hold
value).
Parameter range:
FD-MH10A: 0.00 to 99.99
FD-MH50A: 0.0 to 999.9
FD-MH100A: 0.0 to 999.9
FD-MH500A: 0.0 to 9999.9
R
DINT
0328H
(808)
Instantaneous
flow rate
(bottom hold
value)
*3
Indicates the instantaneous flow rate (bottom
hold value).
Parameter range:
FD-MH10A: 0.00 to 99.99
FD-MH50A: 0.0 to 999.9
FD-MH100A: 0.0 to 999.9
FD-MH500A: 0.0 to 9999.9
R
DINT