Rs-232c, Query control commands – Panasonic AG-DTL1P User Manual
Page 87
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

RS-232C
Query control commands
Data transmitted by PC
Data returned from unit in response
Description of command
[STX] QDP [ETX]
[STX] DPPmm [ETX]
Parameter
mm = C: Center
LB: Bottom left
LT: Top left
RB: Bottom right
RTiTop right
Queries the position where the characters are to be
displayed on the monitor screen.
[STX] QDS [ETX]
[STX] LDSm [ETX]
Parameter
m = i: Field playback
R: Frame playback
Queries whether field playback or frame playback is to be
initiated when still-picture playback is performed.
[STX] QDW [ETX]
[STX] LDWm [ETX]
Parameter
m= W: WARNING
The control signals continue to
be output.
R; REC
The control signals are output
only during recording.
Queries the setting for how the control signals are to be
output to the component connected to WARNING/REC
OUT on the rear panel terminal section when a problem has
occurred in the unit.
[STX] QDX [ETX]
[STX] LDXm [ETX]
Parameter
m= V: VIDEO OUT
Video signal output connector
E: EXTSWIN
External sequential switcher
signal input connector
Queries the function of the EXT SWIN/VIDEO OUT
connector on the rear panel.
[STX] QFS:nn [ETX]
Parameter
nn= 01—12: Free-set timer
number
[STX] LFSnn:mmdd:p [ETX]
Parameter
nn = 00: Free-set timer is not set.
01—12: Free-set timer number
mm - 01—12: Month
dd= 01—31: Day
p = 0: Sunday
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
F: Power OFF throughout the day
Queries the free-set timer setting.
[STX] QHI [ETX]
[STX] HTIm [ETX]
Parameter
m= A: REWIND^REC
R: REC
S: STOP
Queries the unit’s operation mode that Is to be established
when the tape is inserted.
87