Appendix E: Serial Data Output
SkyView System Installation Guide – Revision S
24-11
ZZZZ if the input is not configured
G if the signal is in volume, and the units are 1/10th Gallons
YYYY is 1/10th gallons, so 0183 = 18.3 Gallons
XXXX if the signal is out of range or not calibrated (red X on ems page)
ZZZZ if the input is not configured
V if the signal is in volts (contact input)
YYYY is 1/1000th volts, so 3852 = 3.852V
ZZZZ if the input is not configured
T if the signal is position
If elevator, rudder, and aileron trim, YYYY is percent travel, so 0047 =
47%
If flaps, this is the angle shown on the screen, so 0038 = 38 degrees
XXXX if the signal is out of range or not calibrated (red X on ems page)
ZZZZ if the input is not configured
As an example, the following is one line of DYNON EMS serial output data:
!3221144705060+09323632363272057057164263263000280280+1200001300020+197+592+1
97+592+197+592+197+592+197+592+197+592+197+197-
0012T+0013T+0001T+0164P+1990P+0928C+0001T+0000G+0263G+0263G+0599P+0928C+0928
CZZZZZZZZZZZZZZZZ045L26
DYNON ADAHRS / SYSTEM / EMS Serial Data Output Combinations
DYNON ADAHRS + SYSTEM Serial Data Format
DYNON ADAHRS+SYSTEM output data alternates between DYNON ADAHRS data and DYNON
SYSTEM data. For example, the following is one cycle of DYNON ADAHRS+SYSTEM serial output
data where the first line is ADAHRS output and the next line is SYSTEM output:
!1121144703-014+00003310811+01736+003-03+1013-033+110831245+01650023176C
!2221144704359XXXXX1600+010XXX00XXXXXXXX00X0X+00-
99990+00+99990+00XXXXX00104543XXXXXXXXXX3A
DYNON ADAHRS + EMS Serial Data Format
DYNON ADAHRS+EMS output data alternates between DYNON ADAHRS data and DYNON EMS
data. For example, the following is one cycle of DYNON ADAHRS+EMS output data where the
first line is ADAHRS output and that is followed by EMS output:
!1121144703-014+00003310811+01736+003-03+1013-033+110831245+01650023176C