Dynon Avionics SkyView System Installation Guide User Manual
Page 25
System Planning
SkyView System Installation Guide – Revision S
2-3
Table 3 contains power specifications for SkyView modules that are powered from ship’s power
(not powered by SkyView Network). A 5A circuit breaker is recommend in most cases because
that is the smallest circuit breaker that is commonly available in certified versions.
Unit
Current
requirement
@ 12 volt DC
Current
requirement
@ 24V DC
Circuit
Breaker
Recommendation
SV-ADSB-470
0.2A maximum
0.1A maximum
5A
SV-AP-PANEL
(Trim motor control section)
4.0A maximum
(depends on the trim
motors used)
Not Applicable
5A
SV-COM-C25
3.0A maximum
(transmitting)
1.5A maximum
(transmitting)
5A
SV-COM-X83
2.0A maximum
(transmitting)
1.0A maximum
(transmitting)
5A
SV-XPNDR-261/262
0.4A maximum
0.2A maximum
5A
SV32/SV32C/SV32L
1.3A maximum
(moving 100% torque)
0.7A maximum
(moving 100%
torque)
5A
SV42/SV42C/SV42EL/SV42L/SV42T
2.0A maximum
(moving 100% torque)
1.0A maximum
(moving 100%
torque)
5A
SV52/SV52C/SV52L
2.8A maximum
(moving 100% torque)
1.4A maximum
(moving 100%
torque)
5A
Heated AOA / Pitot Probe
10A (maximum heat)
Not Applicable
10A
Serial to Gray Code Converter
Module
0.01 A (10 mA)
0.05 A (50 mA)
5A
(or add to another fuse or
circuit breaker)
Table 3 – SkyView Modules Power Specifications