Serial connection -3 – Dynon Avionics SkyView System Installation Guide User Manual
Page 189
SV-GPS-250 Installation and Configuration
SkyView System Installation Guide – Revision S
8-3
Serial Connection
SkyView uses the SV-GPS-250 device set to POS 1 as its primary position source.
The SV-GPS-250 includes 18 feet of twisted wire for a serial connection to the SkyView display
via the display. This wire may be trimmed or lengthened as needed to suit the installation.
The color of the SV-GPS-250 wires matches the colors of the wires of the main display harness
that are intended for the GPS serial connection. The following table contains information
regarding the wires.
Function
Harness and SV-GPS-
250 Wire Color
SkyView Display
D37 Pin
SV-GPS-250 Tx /
Serial Port 5 Rx
Gray with
Violet stripe
11
SV-GPS-250 RX /
Serial Port 5 Tx
Gray with
Orange stripe
12
SV-GPS-250 Ground
Black
24
SV-GPS-250 Power
Orange
29
Table 45 – SV-GPS-250 Serial Connection Details
As mentioned before, if there are two or more displays in your SkyView system, all four of the
SV-GPS-250 module’s wires must be connected to all displays in parallel. This wiring scheme is
illustrated in Figure 56.
Figure 56 – SV-GPS-250 Connected to Multiple SkyView Displays