SV-XPNDR-261/262 Installation, Configuration, and Testing

SkyView System Installation Guide – Revision S

11-5

Electrical Connections

Harness Construction

Because the SV-XPNDR-261/262 can be mounted in a variety of locations, the harness length
requirements will vary from airplane to airplane. Therefore, Dynon Avionics does not supply
pre-manufactured harnesses for the SV-XPNDR-261/262. Instead, your SV-XPNDR-261/262
shipped with enough connectors and pins to generate a wide variety of harness configurations.
Refer to the sections below for detailed wiring information. Note that your connector kit may
contain a 1.21K resistor. This is only used for SV-XPNDR-261/262 installations that incorporate a
certified GPS receiver for ADS-B Out functionality.

If you do not own a D-sub machined-pin crimping tool, they can be obtained for under $50 from
many retailers. See http://wiki.dynonavionics.com/Tools_not_supplied_by_Dynon for known
sources of these products. You may also find it helpful to own a pin insertion/extraction tool as
well.

Additional harness construction and wiring information can be found in Appendix C: Wiring and
Electrical Connections.

The SV-XPNDR-261/262 has a single D25 female connector which provides the data and power
inputs to the transponder. A single TNC coaxial connector attaches to the antenna.

SV-XPNDR-261/262 Interface – Pinout (Female D25)

Pin

Function

Notes

1

Loopback 1

Connect to Pin 2

2

Loopback 1

Connect to Pin 1

3

GPS Serial Input

Certified GPS Only for ADS-B Out (see

explanation below)

4

No Connect

-

5

Transponder Serial RX

Data Input from SkyView

6

No Connect

-

7

Transponder Serial TX

Data Output to SkyView

8

No Connect

-

9

No Connect

-

10

No Connect

-

11

No Connect

-

12

Loopback 2

Connect to Pin 13

13

Loopback 2

Connect to Pin 12

14

Ground

Connect to Aircraft Ground