Dynon Avionics SkyView System Installation Guide User Manual
Page 374
Appendix C: Wiring and Electrical Connections
22-16
SkyView System Installation Guide - Revision S
15
11-33V DC
Connect to Aircraft Power
16
No Connect
-
17
External Standby
In
Optional: Not Commonly Connected
18
Mutual
Suppression
Optional: Not Commonly Connected
19
Squat Switch In
Optional: Not Commonly Connected
20
Ident Switch In
Optional: Not Commonly Connected
21
No Connect
-
22
No Connect
-
23
No Connect
-
24
No Connect
-
25
No Connect
-
Table 82 – SV-SPNDR-26X D25 Connector
SV-XPNDR-261/262 Environmental Qualification Forms
Nomenclature:
TT21 Mode S Transponder (Dynon Avionics SV-XPNDR-262)
Part Number: 00675-(XX)
ETSO: 2C112b, C166a
Manufacturer:
Trig Avionics Limited
Address:
Heriot Watt Research Park, Riccarton, Currie, Scotland, EH14 4AP
Conditions
DO-160F
Section
Description of Conducted Tests
Temperature and Altitude
4.0
Equipment tested to Categories A2, C1
Low temperature ground survival
4.5.1
-55°C
Low temperature short-time
operating
4.5.1
-40°C
Low temperature operating
4.5.2
-20°C
High temperature operating
4.5.4
+70°C
High temperature short-time
operating
4.5.3
+70°C
High temperature ground survival
4.5.3
+85°C
Loss of Cooling
4.5.5
Cooling air not required (+70°C operating without cooling air)
Altitude
4.6.1
35,000 feet
Decompression
4.6.2
8,000 to 35,000 feet in 15 seconds
Overpressure
4.6.3
-15,000 feet
Temperature Variation
5.0
Equipment tested to Category C
Humidity
6.0
Equipment tested to Category A
Operational Shocks
7.2
Equipment tested to Category B
Crash Safety
7.3
Equipment tested to Category B type 5
Vibration
8.0
Aircraft zone 2; type 3, 4, 5 to category S level M, type 1 (Helicopters) to
category U level G