Power Consumption Section of the System Planning Chapter for details regarding servo current
consumption at 12 and 24 volts DC.
Circuit Breaker/Fuse
We recommend that electrical power for the autopilot servos be protected with an
appropriately sized circuit breaker or fuse that is accessible to the pilot while in flight.
SkyView continuously communicates with the servos even when the autopilot is disengaged. If
SkyView is operating, but the servos are not receiving power,
PTCH ERR
and
ROLL ERR
will be
displayed in Red on the top bar (AP STATUS area, to the left of the clock). Therefore, we
recommend that the servo power wiring be designed to receive power whenever SkyView is
powered on in routine operation. When the servos are receiving power but the autopilot is not
engaged, the servos draw negligible power.
SkyView Network Connection
Connect the servos to the SkyView network according to Figure 64 and Table 47. Installers
should strongly consider using the SV-NET-SERVO cabling kit (one per servo) for completing the
network connection to the servos in the system. Figure 65 is the recommended pin insertion
scheme for the three D9 connectors present in the SV-NET-SERVO cabling kit.
SV-NET-SERVO Kit
Female DB9 Connector
Pin Insertion View
SV-NET-SERVO Kit
Male DB9 Connector
Pin Insertion View
GREEN
BLUE
WHITE/BLUE
SERVO
(SV32, SV42,
or SV52)
1
5
6
9
SV-NET-SERVO Kit
Female DB9 Connector
Pin Insertion View
CONNECT
1
5
5
6
9
9
WHITE/BLUE
WHITE/GREEN
BLUE
GREEN
1
6
To SkyView
Network
SPLICE
SPLICE
SPLICE
RED
BLACK
YELLOW
RED - 20 AWG - To Servo Power Switch/Breaker
BLACK - 20 AWG - To Aircraft Ground
YELLOW - To Disengage/CWS Button
WHITE/GREEN
All wires in the kit are 20 feet long and 22 AWG unless otherwise specified.
Kit Contents
Figure 65 – SV-NET-SERVO Recommended Pin Insertion (All Connectors Rear View)
Unlike other SkyView Network devices, ONLY the SkyView Network data wires are
routed through the 9-pin connector. The servo Power (Red), Ground (Black), and
Disengage/CWS Button (Yellow) wires are not connected in the 9-pin connector. If
these wires were to connect to SkyView Network signals, the SkyView displays
(which supply power to the SkyView Network) can be damaged and require non-