Dynon Avionics SkyView System Installation Guide User Manual
Page 124
SV-EMS-220/221 Installation and Configuration
7-12
SkyView System Installation Guide - Revision S
installations that differ significantly from these standard installations should be designed to not
exceed the following current limitations:
EMS
Module
Output
Pin
Output
Current
Limit
Wire Color
Current Draw of Sensors that Use This Output
12V
15
80mA
Red
FloScan Fuel Flow Sensor (100403-001): 50mA
EI Fuel Flow Sensor (100403-003): 15mA
UMA Differential Fuel Pressure: 10mA
Rotax Honeywell Oil Pressure Sensor: 20mA
Rotax Oil Pressure Sensor
P/N 456180: 20mA
Dynon Capacitance to Voltage Converter: 25mA
5V
18
300mA
(Limited
by
internal
self-
resetting
fuse)
White/Red
Kavlico pressure sensors: 5mA
3
rd
party trim and flaps position: 5mA
Manifold pressure sensor (100434-000): 10mA
Table 17 – EMS Module Current Draw Limits for 5/12V Lines
Example Engine Sensor and Transducer Installations
This section contains example engine sensor and transducer installations for popular engines.
Each engine subsection listed on the following pages contains tables for each SV-EMS-220/221
connector and suggests a way to connect that engine’s required sensors to the EMS module.
These tables are based on the downloadable mapping and settings files available from Dynon’s
support forums and may need to be modified based on your particular installation.