SV-EMS-220/221 Installation and Configuration
SkyView System Installation Guide – Revision S
7-69
Example Contact Sensor Setup
Assume this sensor was mapped on the Sensor Input Mapping Wizard as:
PIN #
FUNCTION
SENSOR
NAME
C37 P9
CANOPY
Contact
CANOPY
Now, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu and
open the CANOPY CONTACT Page (SETUP MENU > EMS SETUP > SENSOR SETUP > CANOPY
CONTACT).
Note that although inputs set up as contacts can physically accept up to 15V (so
that they can accept nominal aircraft voltage as one of their two states), the
maximum the EMS can measure is 5.0V. This means that as depicted below, the
two measured ranges should be set to 0-2.5V and 2.5-5V to measure the absence
and presence of power.
Configure CANOPY CONTACT with the following properties:
ALARM:
OFF
MAXIMUM GRAPHICAL DISPLAY:
5.0 VOLTS
MINIMUM GRAPHICAL DISPLAY:
0.0 VOLTS
RANGE 1
o ENABLE
YES
o NAME
OPEN
o COLOR
RED
o TOP
5.0 VOLTS
o BOTTOM
2.5 VOLTS
RANGE 2
o ENABLE
YES
o NAME
CLOSED
o COLOR
GREEN
o TOP
2.5 VOLTS
o BOTTOM
0.0 VOLTS
RANGE 3
o ENABLE
NO
o NAME
R3
o COLOR
GREEN
o TOP
20.0 VOLTS
o BOTTOM
10.0 VOLTS
RANGE 4
o ENABLE
NO
o NAME
R4
o COLOR
YELLOW
o TOP
10.0 VOLTS
o BOTTOM
5.0 VOLTS
RANGE 5
o ENABLE
NO
Figure 48 –
Anatomy of a
Widget:
Canopy
Contact