Dynon Avionics SkyView System Installation Guide User Manual
Page 370
Appendix C: Wiring and Electrical Connections
22-12
SkyView System Installation Guide - Revision S
SV-EMS-221 D37
Pin
EMS 37-pin Harness Wire
Color
Sensor (with Dynon part number if
applicable)
1
Red
Voltmeter 1 (0 to 30 volts DC)
2
Yellow or Unwired
Voltmeter 2 (0 to 30 volts DC)
3
Black
Signal Ground
4
Violet/Blue
General Purpose Input 1
5
Black
Signal Ground
6
White/Yellow
General Purpose Input 11
7
White/Brown
General Purpose Input 12
8
Brown
Enhanced General Purpose Input 4
9
Brown/Blue
General Purpose Input 5
10
Brown/Yellow
General Purpose Input 6
11
Orange
General Purpose Input 7
12
Yellow
General Purpose Input 8
13
Black
Signal Ground
14
Yellow
Fuel Flow Input 1
15
Red
+12 volts DC Auxiliary Power Output
16
Black
Signal Ground
17
Black
Signal Ground
18
White/Red
+5 volts DC Auxiliary Power Output
(Limited to 300 mA by internal self-
resetting fuse)
19
White/Black
Fuel Flow Input 2
20
Orange/Brown
General Purpose Input 9
21
Orange/Blue
General Purpose Input 10
22
Violet/Yellow
Enhanced General Purpose Input 2
23
Violet/Green
Enhanced General Purpose Input 3
24
Orange/Green
Amps+ Input
25
Orange/Violet
Amps- Input
26
Green/Red
Manifold Pressure Input
27
Open
RPM Signal to Rotax 912 iS Prop Controller
(optional)
28
Open
NOTE: Must be grounded to common
ground with Prop Controller
29
Yellow/Green
Optional External Alarm Light
30
Black
Signal Ground
31
White/Orange
Enhanced General Purpose Input 13
32
White/Green
Standard RPM Left Input
33
White/Blue
Standard RPM Right Input
34
Blue
Low Voltage RPM Left Input
35
Green
Low Voltage RPM Right Input
36
Blue or Unwired
CAN High from 912 iS ECU
37
Green or Unwired
CAN Low CAN High from 912 iS ECU
Table 78 – SV-EMS-221 Male D37 Transducer Connector