Dynon Avionics SkyView System Installation Guide User Manual
Page 183
SV-EMS-220/221 Installation and Configuration
SkyView System Installation Guide – Revision S
7-71
Example Oil Temperature Sensor Setup
Assume this sensor was mapped on the Sensor Input Mapping Wizard as:
PIN #
FUNCTION
SENSOR
NAME
C37 P7
TEMPERATURE
5/8”-18 NPT FLUID TEMP (100409-000)
OIL
Now, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu and
open the OIL TEMPERATURE Page (SETUP MENU > EMS SETUP > SENSOR SETUP > OIL
TEMPERATURE).
Configure OIL TEMPERATURE with the following properties:
ALARM:
LATCHING
MAXIMUM GRAPHICAL DISPLAY:
260 °F
MINIMUM GRAPHICAL DISPLAY:
80 °F
SHOW SENSOR UNITS
YES
RANGE 1
o ENABLE
YES
o COLOR
YELLOW
o TOP
165 °F
o BOTTOM
80 °F
RANGE 2
o ENABLE
YES
o COLOR
GREEN
o TOP
220 °F
o BOTTOM
165 °F
RANGE 3
o ENABLE
YES
o COLOR
YELLOW
o TOP
240 °F
o BOTTOM
220 °F
RANGE 4
o ENABLE
YES
o COLOR
RED
o TOP
260 °F
o BOTTOM
240 °F
RANGE 5
o ENABLE
NO
o COLOR
RED
o TOP
5 °F
o BOTTOM
0 °F
Note that oil temperature is configured with a latching alarm in this example. If oil
temperature ever reaches a range configured as red, an alarm will trigger and a
Figure 50 –
Anatomy of a
Widget: Oil
Temperature