Dynon Avionics SkyView System Installation Guide User Manual
Page 375
`
Appendix C: Wiring and Electrical Connections
SkyView System Installation Guide – Revision S
22-17
Explosion
9.0
Equipment identified as Category X
– no test required
Waterproofness
10.0
Equipment identified as Category X
– no test required
Fluids Susceptibility
11.0
Equipment identified as Category X
– no test required
Sand and Dust
12.0
Equipment identified as Category X
– no test required
Fungus
13.0
Equipment identified as Category X
– no test required
Salt Spray
14.0
Equipment identified as Category X
– no test required
Magnetic Effect
15.0
Equipment tested to Category Z
Power Input
16.0
Equipment tested to Category BX
Voltage Spike
17.0
Equipment tested to Category B
Audio frequency conducted
susceptibility
18.0
Equipment tested to Category B
Induced signal susceptibility
19.0
Equipment tested to Category AC
Radio frequency susceptibility
20.0
Equipment tested to Category TT
Radio frequency emission
21.0
Equipment tested to Category B
Lightning induced transient
susceptibility
22.0
Equipment identified as Category XXXX
– no test required
Lightning direct effects
23.0
Equipment identified as Category X
– no test required
Icing
24.0
Equipment identified as Category X
– no test required
Electrostatic Discharge
25.0
Equipment identified as Category X
– no test required
Fire, Flammability
26.0
Equipment identified as Category C
Nomenclature:
TT22 Mode S Transponder (Dynon Avionics SV-XPNDR-261)
Part Number: 00745-(XX)
ETSO: 2C112b, C166a
Manufacturer:
Trig Avionics Limited
Address:
Heriot Watt Research Park, Riccarton, Currie, Scotland, EH14 4AP
Conditions
DO-160F
Section
Description of Conducted Tests
Temperature and Altitude
4.0
Equipment tested to Categories A2, C1
Low temperature ground survival
4.5.1
-55°C
Low temperature short-time
operating
4.5.1
-40°C
Low temperature operating
4.5.2
-20°C
High temperature operating
4.5.4
+70°C
High temperature short-time
operating
4.5.3
+70°C
High temperature ground survival
4.5.3
+85°C
Loss of Cooling
4.5.5
Cooling air not required (+70°C operating without cooling air)
Altitude
4.6.1
35,000 feet
Decompression
4.6.2
8,000 to 35,000 feet in 15 seconds
Overpressure
4.6.3
-15,000 feet
Temperature Variation
5.0
Equipment tested to Category C
Humidity
6.0
Equipment tested to Category A
Operational Shocks
7.2
Equipment tested to Category B
Crash Safety
7.3
Equipment tested to Category B type 5