beautypg.com

B&C Technologies DI-325 Industrial User Manual

Page 69

background image

OPERATING AND PROGRAMMING INSTRUCTIONS

8-38

(34) Maintenance request
The maintenance request counter is 0 and the machine needs maintenance. The number of

batches which can be done between 2 maintenance requests is adjustable with machine parameter
5). Resetting the maintenance request can be done via the ‘System Set-up’ menu (see chapter 6.6.4).

(36) Waiting for cycle restart
While a program was running the machine was stopped, either by an alarm or by pushing

the stop button. If the start button is pushed the machine will continue its cycle. If the stop button is
pushed the program cycle will be stopped.

(37) Program finished
A program is finished. If the door is opened the machine will finish and start from the

beginning again.

(38) Press

to start

The machine is ready to start a new program. If the start button is pushed, and all inputs are

okay, a program cycle will start.

8 Default settings and default programs

When the DQ 01 controller is delivered, or when factory settings are recalled (see chapter

6.6.3), default programs and default machine parameters will be available.

8.1 Default program settings and default programs

Because the used language can vary, no default program names are set, except for program

100, which will be called ‘Single cycle’.

All programs are set to the following default values:
01

Drying

method TIME

03

Min.

drying

time

10

m

04

Max.

Drying

time

45

m

05

Drying

time

40

m

07

Dry temperature

167 °F / 75 °C

08

Offset sensor 2

2 °F / °C

09

Offset

infrared

4

°F

/

°C

10

Humidity

dry

val.

15%

18

Cooldown

time 10

m

19

Cooldown temp.

95 °F / 35 °C

23

Drum

direction REV

24

Drum

speed

100

%

25

Drum

stop

time 1

s

26

Drum

run

time

45

s

29

Anti

crease

funct.

YES

32

Max.

temp.

rise 0

°/m

33

Max.

temp.

fall 0

°/m

In the default programs, some parameter values are set to a different value to provide

different programs to start with. The following default programs are available: