beautypg.com

B&C Technologies DI-325 Industrial User Manual

Page 22

background image

INSTALLATION PROCEDURES

3-13













Figure.3-6 Steam Damper System Operation


5.

Steam Damper Air Cylinder (Flow Control) Operation Adjustment

Damper operation was tested and adjusted prior to shipping at 80 psi. If damper air

adjustment is necessary, locate flow control valve and make necessary adjustments.


















Figure.3-7 Steam Damper Air Cylinder

Adjustment



The following items should be checked before attempting to operate the dryer:

1.

Read and follow all “caution”, “warning” and “direction” labels attached to the dryer.

2.

Check incoming supply voltage to be sure that it is the same as indicated on the dryer data
label affixed behind the right control box door. In the case of 208V AC or 230/240V AC, the
supply voltage must match the electric service exactly.

3.

Check to be sure drive belts between idler pulley and motor pulley have been re – connected.


NOTE:

The drive belts were disconnected at factory prior to shipment.

I. PREPARATION FOR OPERTION/START-UP