INSTALLATION PROCEDURES

3-12

b.

Air Connection

Air connection to system size 10 mm.

























Figure.3-5 Air Connection

c.

No air regulation is provided with the dryer

External regulation of 80 psi must be provided. It is suggested that a regulator / fitter

gauge arrangement be added to the compressed air line just before the dryer connection. This is
necessary to insure that correct and clean air pressure is achieved.


4.

Steam Damper System Operation

The dryer model 325 lbs steam dampers allow the coil to stay constantly charged

eliminating repeated expansion and contraction. When the damper is opened, the air immediately
passes through the already hot coil, providing instant heat to start the drying process. When the
damper is closed, ambient air is drawn directly into the basket (tumbler), allowing a rapid cool
down.

Diagram 1 shows the damper in the heating (open) mode, allowing heat into the basket

(tumbler).

Diagram 2 shows the damper in the cool (closed) mode, pulling ambient air directly into the

basket (tumbler) without passing through the coils.

NOTE:

With the dryer off or with no air supply, the damper is in the cool down mode.