pieces which are currently dried. For example, if this parameter is set to 175°C, the heating output
will be switched off when the inlet temperature sensor (sensor 2) measures a temperature higher
than 175°C.
(18) Cooldown time
The maximum time the cool-down step may last. If the adjusted cool-down temperature
(parameter 19) is not reached within this time, the program will finish anyway.
(19) Cooldown temperature
The target temperature in the cool-down step. If this temperature is reached in the cool-
down step, the program will finish.
(23) Drum direction
The direction of the drum during drying, cool-down and anti-crease. If a reversible drum is
configured in the machine configuration (see chapter 6.8), this parameter can be used to set the
drum direction.
Left: Only turn left (output 5), drum will never stop
Right: Only turn right (output 6), drum will never stop
Rev: Toggle between left (output 5) and right (output 6), runtime and stop time adjustable with
program parameters 15 and 16)
If no reversible drum is configured, this parameter will not be visible.
(24) Drum speed
If the machine is equipped with a drum with frequency inverter (see chapter 6.8, machine
configuration), this parameter can be used to adjust the drum speed during drying, cool-down and
anti-crease. The value of this parameter is a percentage of the maximum speed. So if this parameter
is set to 50%, the drum will run at half the maximum speed.
When no drum with frequency inverter is installed, this parameter will not be visible.
(25) Drum stop time
If the machine is equipped with a reversible drum motor, and program parameter 13 is set to
reversing, this parameter allows the time the drum will stop when switching direction to be defined.
So, after running for the time defined in parameter 16, the drum will stop for the time defined in
parameter 15 and then start again in the other direction.
If no reversible drum is installed or the drum direction is not set to reverse, this parameter
will not be visible.
NOTE: This value is an additional value to the minimum stop time, which is 4 seconds. So, for
example, if this parameter is set to a value of 6, the stop time will be 6 + 4 = 10 seconds.
(26) Drum run time
If the machine is equipped with a reversible drum motor, and program parameter 13 is set to
reversing, this parameter is the time the drum runs in one direction. After running for the time
defined in parameter 16, the drum will stop for the time defined in parameter 15 and then start again
in the other direction.
If no reversible drum is installed or the drum direction is not set to reverse, this parameter
will not be visible.