Carrier Access Multi-Service Router (MSR) Card MSR/Adit 3K GUI User Manual
Page 219
Adit 3000 (Rel. 1.6) and MSR Card (Rel 2.0) GUI
6-13
Voice over IP
IP Telephony
When the primary proxy is not reachable or returns an error, the system initiates a rollover (the next
server in the list is used, until a working server replies).
When the last server in the list fails, the rollover is considered a rollback. The route advance timeout
will not take effect for 30 seconds and retransmission timers will take precedence. After 30 seconds,
the primary proxy (first in the list) will be treated as active again.
Field
Definition
BroadSoft Proxy/Outbound Proxy Redundancy
Global Redundancy
Configuration
None - Redundancy feature is disabled. Default.
SRV - An SRV lookup will be performed using the main proxy. The
hosts/IPs found are used to form the proxy redundancy list.
User - The SIP messages will be sent to the primary proxy. If there is
a failure, it will be sent to the secondary proxy.
SRV Time to Live
(seconds)
A set interval of time between flushing the SRV cache. Range is
0 - 3600 seconds, with a default of 3600 (1 hr.).
0 = Cancel this feature.
Note: This field appears only when SRV is selected in the Global
Redundancy Configuration field.
Primary Proxy
Enter Primary Outbound Proxy address. Note: This field appears
only when User is selected in the Global Redundancy Configuration
field.
Secondary Proxy
Enter Secondary Outbound Proxy address. Note: This field appears
only when User is selected in the Global Redundancy Configuration
field.
Filter Packets from
Unknown SIP Servers
Select checkbox to enable filtering.
Router Advance Timeout
(seconds)
A set interval of time before moving onto the next proxy when the
first is not reachable. Range is 0 - 10 seconds, with a default of 2.
Route Advance Retries
A set number of retries before a proxy is considered unreachable and
moving onto the next. Range is 0 - 10, with a default of 3.
Primary Rollback Timer
(seconds)
A set interval of time between the time the primary proxy fails and
when a rollback is performed back to the primary proxy. Range is 60
to 3600 seconds or 0 (disabled). Default is 300 seconds (5 minutes).
Force Rollback (button) - When this button is selected, the primary proxy will be considered active
and all new subsequent transactions will be sent to the primary. Normal rollover will apply after this.
Priority
Displayed by priority.
Name
Host name.
Port
Proxy port.
IP
Host IP address.
Selected
Indicates current proxy.