Off on, Continued, Smartcode user selectable settings – Weiser SmartCode5 - Traditional & Contemporary User Manual
Page 7

7
9. Continued.......
a. Press the program button on the interior unit twice.
b. Enter in 4 to 8 digit code onto the keypad.
c. Press the “LOCK” button to save code.
d.
Note: Programming instructions can also be found on interior of lock.
Programming the 2nd user code.
Extend the bolt by pressing the “LOCK” button and re-enter the code
to test. The bolt should retract to the unlocked position. If it does not
unlock, repeat steps (a) through (c).
10. SmartCode User Selectable Settings.
Switch #2 Enables the AUTO LOCK when
in the ON position. With Auto Lock enabled,
SmartCode will automatically relock the door
(extend the bolt) 30 seconds after unlocking.
Switches
ON
1
2
3
4
LED
Switch #1
Status LED blinks every
5 seconds when in the ON position. Note:
The low battery RED LED cannot be
disabled.
Switch
Position
OFF
ON
LED
Color
Green
Orange
Red
Unlocked
Locked
Low Battery
Lock
Status
Red
Low Battery
Hint: for easier access, use a ball point pen to operate the switches.
Switch #4 Extra switch with NO FUNCTION.
Switch #3 Enables the AUDIO sound (Beeper) when in the ON
position. Keypad will now light red/green when buttons are pressed.
CAUTION: Prevent unauthorized entry. This lock can be opened
using two different codes that are randomly set at the factory. Upon in-
stallation and set-up, replace both of these codes with your own. Since
anyone with access to the power board can change these codes, you
must restrict access to the power board and routinely check both codes
to assure they have not been altered without your knowledge.