Weiser Removing and Replacing Cylinder of Entry Knob User Manual
Weiser For Home
For Inswinging Door
For Outswinging Door
Inside
Outside
Inside
Outside
Left Hand
Right Hand
Left Hand
Right Hand
1
2
4
3
7
2
5
6
3
4
1412 Keying Kit
28739/01
3.
Insert cylinder removing tool (2) edgewise between screw stem (5) and
the detent slide (6) rotating tool clockwise to position shown. Apply slight
leverage to remove spring tension while holding spindle downwards
allowing spindle to drop out. If necessary use free thumb to assist removal.
If spindle rotates, repeat step 2.
4.
Insert cylinder removing tool in lock housing (7) pushing together
cylinder retaining springs by moving tool up and down and push cylinder
out of knob. If door not available, note position of cylinder in knob for
reassembly.
5.
Replace round spindle by lining up boss (3) with slot (4) and push
spindle until the detent spring snaps into place.
7.
Position cylinder so that pin cover and key cuts are in the upward
position (as shown in illustration). Align cylinder with guides in knob and
insert, pressing until retaining springs snap into position.
2.
Rotate Round Spindle (1) with cylinder removing tool (2) to line up
boss (3) with slot (4).
1.
Remove key from Cylinder.
6.
Install knob on door if door is available.
8.
If key will not remove, begin again at step “A” and insure step ”E”
procedures are followed.
The hand of a door is always determined by facing the outside of a door.
If the hinge is on the left side of the door, then the door is left-handed.
If the hinge is on the right side of the door, then the door is right-handed
.
C.
REMOVE CYLINDER
A.
ALIGN SPINDLE
B.
REMOVE SPINDLE
D.
REPLACE SPINDLE
E.
REPLACE CYLINDER
F.
HOW TO DETERMINE HAND OF DOOR
Instructions for Removing and Replacing Cylinder of Entry Knob.
WARNING: This Manufacturer advises that no lock can provide complete security by itself. This lock may be defeated by forcible or technical means, or evaded by entry
elsewhere on the property. No lock can substitute for caution, awareness of your environment, and common sense. Builder’s hardware is available in multiple performance
grades to suit the application. In order to enhance security and reduce risk, you should consult a qualified locksmith or other security professional.
PIN COVER UP
KEY CUTS UP
RETAINING