Setpoints
77
DIGIN
Digital input setpoint. Requires a specific group of digital inputs to be in low (0
VDC) state to satisfy the setpoint. The digital output associated with this
setpoint is held in a low (0 VDC) state until the inputs selected for the digital
input mask are all in a low state.
X
X
AVG
Average setpoint. Performs functions based on the calculated average weight
over a specified number of A/D samples.
Note that this setpoint is based on the raw A/D weight value, rather than the
rounded value shown on the indicator display. For example, if the display shows
50.0 but the actual raw A/D value is 49.99, the setpoint will not be satisfied.
X
TOD
Time of day setpoint. Performs functions when the internal clock time of the
indicator matches the specified setpoint time.
X
X
DELTA
Delta weight setpoint. Satisfied when the change in weight on the scale is equal
to or exceeds the absolute value specified for the setpoint.
X
CHKWEI
Checkweigher setpoint. Allows specification of over- and under-weight values.
Up to three digital outputs can be configured to represent overweight,
underweight, and accept conditions.
X
PLSCNT
Pulse counter setpoint. Performs functions based on pulse counts received by
a pulse input card.
X
X
PLSRAT
Pulse rate setpoint. Performs functions based on the pulse rate received by a
pulse input card.
X
ALWAYS
Always setpoint. This setpoint is always satisfied. It is typically used to provide
an endpoint for true/false branching batch routines.
X
NEVER
Never setpoint. This setpoint is never satisfied. It is used to branch to a
designated setpoint in true/false branching batch routines in which the batch
will not continue through the normal sequence of batch setpoints.
X
DINCNT
Digital input count setpoint. Counts pulses received at the specified digital
input.
X
X
Kind
Description
Batch
Continuous
Table 9-1. Setpoint Kinds (Continued)