Rice Lake 920i USB Installation Manual V5.05 User Manual
Page 103

Serial Commands
97
SC.TER.DECPNT#n
Tertiary units decimal position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800
SC.TER.DSPDIV#n
Tertiary units display divisions
1D, 2D, 5D
SC.TER.MULT#n
Tertiary units multiplier
0.000001–9999999
SC.ROC.DECPNT#n
Tertiary units decimal position
8.888888, 88.88888, 888.8888, 8888.888, 88888.88, 888888.8,
8888888, 8888880, 8888800
SC.ROC.DSPDIV#n
Rate-of-change units display
divisions
1D, 2D, 5D
SC.ROC.MULT#n
Rate-of-change units multiplier 0.000001–9999999
SC.ROC.UNITS#n
Rate-of-change units
SEC, MIN, HOUR
SC.ROC.INTERVL#n
Rate-of-change interval
1–100
SC.ROC.REFRESH#n
Rate-of-change refresh
interval
0.1–60
SC.RANGE1.MAX#n
Weight maximum for first
range or interval
weight
SC.RANGE2.MAX#n
Weight maximum for second
range or interval
weight
SC.RANGE3.MAX#n
Weight maximum for third
range or interval
weight
SC.ACCUM#n
Accumulator enable
ON, OFF
SC.VISIBLE#n
Scale visibility
ON, OFF
SC.PEAKHOLD#n
Peak hold
OFF, NORMAL, BI-DIR, AUTO
SC.WZERO#n
Zero calibration
—
SC.WVAL#n
Test weight value
test_weight_value
SC.WSPAN#n
Span calibration
—
SC.WLIN.F1#n–
SC.WLIN.F5#n
Actual raw count value for
linearization points 1–5
0–16777215
SC.WLIN.V1#n–
SC.WLIN.V5#n
Test weight value for
linearization points 1–5
0.000001–9999999
SC.WLIN.C1#n–
SC.WLIN.C5#n
Calibrate linearization points
1–5
—
SC.LC.CD#n
Deadload coefficient
—
SC.LC.CW#n
Span coefficient
—
SC.LC.CZ#n
Temporary zero
—
SC.REZERO#n
Rezero
—
For commands ending with “#n”, n is the scale number.
Command
Description
Values