Rice Lake 920i USB Installation Manual V5.05 User Manual
Page 108

Table 10-9. DIG I/O Serial Commands
Command
Description
Values
DON.b#s
Set digital output on (active) at bit b, slot s.
—
DOFF.b#s
Set digital output off (inactive) at bit b, slot s.
—
DIO.b#s
Digital input function
OFF, INPUT, OUTPUT, PROGIN, ZERO, NT/GRS,
TARE, UNITS, PRINT, ACCUM, SETPNT,
TIMDATE, ESC, CLEAR, DSPTAR, IDKEY,
KEY0–KEY9, KEYDP, ENTER, NAVUP, NAVDN,
NAVLFT, NAVRGT, KBDLOC, HOLD, BATRUN,
BATSTRT, BATPAUS, BATRESET, BATSTOP,
CLRCN, GROSS, NET, PRIM, SEC, CLRTAR,
CLRACC, TRIGGER
DIO.TRIG_SLOT.b#s
Trigger output slot
NONE, SLOT3
DIO.TRIG_PARAM.b#s
Trigger output parameter
value
Digital inputs and outputs are specified by bit number (b) and slot number (s)
Table 10-10. ALGOUT Serial Commands (Valid Only If Analog Output Card Is Installed)
Command
Description
Values
ALG.ALIAS#s
Analog output alias
name
ALG.SOURCE#s
Analog output source
PROG, SCALEn
ALG.MODE#s
Mode
GROSS, NET
ALG.OFFSET#s
Zero offset
0%, 20%
ALG.ERRACT#s
Error action
FULLSC, HOLD, ZEROSC
ALG.MIN#s
Minimum value tracked
0–9999999
ALG.MINNEG#n
Minimum value is negative
OFF, ON
ALG.MAX#s
Maximum value tracked
0–9999999
ALG.MAXNEG#n
Maximum value is negative
OFF, ON
ALG.ZERO#s
Zero calibration
0–65535
ALG.SPAN#s
Span calibration
0–65535
For commands ending with “#s”, s is the slot number. For dual-channel analog output cards,channel 2 is assigned to
ALGOUTs+14. For example, channel 2 of a dual analog output card in Slot 3 is assigned ALGOUT17.
Table 10-11. FLDBUS Serial Commands (Valid Only If Fieldbus Card Is Installed)
Command
Description
Values
FB.BYTESWAP#s
Swap data bytes
NONE, BYTE, WORD, BOTH
FB.SIZE#s
Number of bytes to transfer
2–128
For commands ending with “#s”, s is the slot number.
Table 10-12. Analog Input Serial Commands (Valid Only If Analog Input Card Is Installed)
Command
Description
Values
XP#s
Extract probe temperature
—
XPP#s
Extract probe primary temperature
XPS#s
Extract probe secondary temperature
XPT#s
Extract probe tertiary temperature
XI#s
Extract 0–20 mA value
XV#s
Extract 0–10 V value
For commands ending with “#s”, s is the slot number.
102
920i Installation Manual