Rice Lake 920i USB Installation Manual V5.05 User Manual
Page 104

Table 10-5. SERIAL Port Serial Commands
Command
Description
Values
EDP.INPUT#p
Port serial input function
CMD, KEYBD, KBDPRG, SCALE, IND SC, DISPLAY, IQUBE2
See the
iQUBE
2
Installation Manual, PN 106113, for more
information about configuring
iQUBE
serial scales.
EDP.BAUD#p
Port baud rate
300, 600, 1200, 2400, 4800, 9600, 19200, 28800, 38400, 57600,
115200
EDP.BITS#p
Port data bits/parity
8NONE, 7EVEN, 7ODD, 8ODD, 8EVEN
EDP.TERMIN#p
Port termination character
CR/LF, CR
EDP.STOPBITS#p
Port stop bits
2, 1
EDP.ECHO#p
Port echo
ON, OFF
EDP.RESPONSE#p
Poer response
ON, OFF
EDP.EOLDLY#p
Port end-of-line delay
0–255 (0.1-second intervals)
EDP.HANDSHK#p
Port handshaking
OFF, XONXOFF, HRDWAR
EDP.PORTTYPE#p
Port type
232, 485
EDP.DUPLEX#p
Port RS-485 duplex
HALF, FULL
EDP.ADDRESS#p
Port RS-485 address
0, 1–255
EDP.STREAM#p
Port streaming
OFF, LFT, INDUST, 4KEYS, KEYPAD, DISPLAY
EDP.SOURCE#p
Port source scale for output
scale_number
EDP.SFMT#p
Port custom stream format
0-50 characters
STR.POS#p
Custom stream identifiers
Specify replacement text for token
Example: STR.PRI#1=L
See Section 11.6 on page 118 for more information about custom
stream formatting.
STR.NEG#p
STR.PRI#p
STR.SEC#p
STR.TER#p
STR.GROSS#p
STR.NET#p
STR.TARE#p
STR.MOTION#p
STR.RANGE#p
STR.OK#p
STR.INVALID#p
STR.ZERO#p
For commands including “#p”, p is the serial port number.
98
920i Installation Manual
Command
Description
Values
SD
Set date
MMDDYY, DDMMYY, YYMMDD, or YYDDMM. Enter six-digit
date using the year-month-day order specified for the
DATEFMT parameter, using only the last two digits of the year.
ST
Set time
hhmm (enter using 24-hour format)
DATEFMT
Date format
MMDDYYYY, DDMMYYYY, YYYYMMDD, YYYYDDMM
DATESEP
Date separator
SLASH, DASH, SEMI
TIMEFMT
Time format
12HOUR, 24HOUR
TIMESEP
Time separator
COLON, COMMA
Table 10-6. FEATURE Serial Commands