2 usb commands, 3 reporting commands, 4 clear and reset commands – Rice Lake 920i USB Installation Manual V5.05 User Manual
Page 101: 5 parameter setting commands, Usb commands, Reporting commands, Clear and reset commands, Parameter setting commands

Serial Commands
95
10.1.2
USB Commands
Command
Function
USB.INSTALLED
Returns whether USB interface
card is installed (TRUE or
FALSE).
USB.DEVICE
Returns configured device from
the last Save and Exit. This can
be changed only in setup mode.
USB.DEVICE.LOAD
Applies the configured device
selected from the USB.DEVICE
command.
USB.DEVICE.CURRENT
Returns the current device
Table 10-2. USB Commands
10.1.3
Reporting Commands
Reporting commands send specific information to the
serial port. The commands listed in Table 10-3 can be
used in either setup mode and normal mode.
Table 10-3. Reporting Commands
Command
Function
DUMPALL
List all parameter values
SPDUMP
Print setpoint configuration
VERSION
Write 920i software version
HARDWARE
Lists option cards installed in slots 1–14.
See Section 11.1.2 on page 113 for more
information about using the HARDWARE
command.
HWSUPPORT
Reports the CPU part number (67612 = old)
(109549 = new)
XE
Returns a10-digit code representing any
error conditions currently shown on the
front panel. See Section 11.1.4 on
page 114 for more information.
10.1.4
Clear and Reset Commands
The following commands can be used to clear and reset
the 920i:
PCLR
: Program clear. Erases the loaded user program
(setup mode only).
RS
: Reset system. Resets the indicator without
resetting the configuration.
RESETCONFIGURATION
: Restores all configuration
parameters to their default values (setup mode
only). The
RESETCONFIGURATION
function can
also be initiated by pressing the
Reset Config
softkey under the VERSION menu. Use the
up
key
to select
Clear entire indicator configuration
, then press
ENTER
to reset the indicator.
Note
All load cell calibration settings are lost when
the RESETCONFIGURATION command is run.
10.1.5
Parameter Setting Commands
Parameter setting commands allow you to display or
change the current value for a particular configuration
parameter (Tables 10-4 through 10-13).
Current configuration parameter settings can be
displayed in either setup mode or normal mode using
the following syntax:
command
Most parameter values can be changed in setup mode
only; setpoint parameters listed in Table 10-7 on
page 100 can be changed when in normal weighing
mode.
Use the following command syntax when changing
parameter values:
command=value
, where
value
is either a number or a parameter value. Use no spaces
before or after the equal (=) sign. If you type an
incorrect command, the display reads
??
.
For example, to set the motion band parameter on Scale
#1 to 5 divisions, type the following:
SC.MOTBAND#1=5D
For parameters with selectable values, enter the
command and equal sign followed by a question mark:
command=?
to see a list of those values. The
indicator must be in setup mode to use this function.
Note
Some parameters are valid only if other
parameters or parameter values are specified.
See the configuration menus in Section 3.2 on
page 25 for information about parameter
dependencies. Restrictions for front-panel
configuration also apply to serial command
configuration.