Rice Lake 920i USB Installation Manual V5.05 User Manual
Page 52

46
920i Installation Manual
SOFTKEYS
Time/Date
Display Tare
Display Accum
Display ROC
Setpoint
Batch Start
Batch Stop
Batch Pause
Batch Reset
Weigh In
Weigh Out
Truck Regs
Unit ID
Select Scale
Alibi
Diagnostics
Contrast
Test
Stop
Go
Off
Screen
F1–F10
USB
Use the Add and Remove softkeys to select softkeys to be displayed in weighing mode.
KYBDLK
OFF
ON
Keyboard lock. Specify ON to disable the keypad in normal mode.
ZERONLY
OFF
ON
Zero key only. Specify ON to disable all front panel keys except ZERO in normal mode.
PROMPTS
PROMPT1–
PROMPT60
Specify prompts for use in setpoint names. Prompts are referenced by the NAME parameter
under the SETPTS submenus; prompts can be shown on the display during setpoint
execution.
REGULAT
NTEP
CANADA
INDUST
NONE
OIML
Regulatory mode. Specifies the regulatory agency having jurisdiction over the scale site.
• OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater
than zero. NONE allows tares to be acquired at any weight value.
• OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is
at no load. NONE allows tares to be cleared at any weight value.
• NTEP and OIML modes allow a new tare to be acquired even if a tare is already
present. In CANADA mode, the previous tare must be cleared before a new tare can be
acquired.
• NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net
mode as long as the current weight is within the specified ZRANGE. In OIML mode, the
scale must be in gross mode before it can be zeroed; pressing the ZERO key in net
mode clears the tare.
• INDUST provides a set of subparameters to allow customization of tare, clear, and print
functions in non-legal-for-trade scale installations. See Level 4 parameter descriptions
in Table 3-9 on page 49.
The value specified for this parameter affects the function of the front panel TARE and ZERO
keys. See Section 11.2 on page 115 for a complete description of TARE and ZERO key
functions for each of the regulatory modes.
REGWORD
GROSS
BRUTTO
Sets the term displayed when weighing in gross mode. Selecting BRUTTO replaces the
Gross annunciator with Brutto.
CONTACT
—
Allows specification of contact information for use in iQUBE
2
alert messages. See Level 3
submenu descriptions in Table 3-8 on page 48.
FEATURE Menu
Parameter
Choices
Description
Table 3-7. FEATURE Menu Parameters (Continued)